| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 16:39:35 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
72 |
07/03/2026 22:30:18 |
|
1606 |
Elevator Failure Car door closing failed, too many closing trials
|
32 |
08/03/2026 09:40:22 |
|
1702 |
Elevator Failure Start timeout
|
23 |
08/03/2026 09:45:15 |
|
1607 |
Elevator Failure Reopen device active too long
|
9 |
18/01/2026 00:00:19 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
8 |
09/03/2026 11:11:01 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
8 |
09/03/2026 11:11:00 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
8 |
09/03/2026 11:11:01 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
4 |
09/03/2026 11:11:01 |
|
1181 |
Elevator Failure Door bypass switch misuse |
4 |
09/03/2026 11:09:44 |
|
1830 |
Elevator Failure LON communication error
|
2 |
16/01/2026 02:38:47 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
16/01/2026 02:39:05 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
16/01/2026 02:39:05 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
1 |
24/02/2026 13:16:07 |