1607 |
Elevator Failure Reopen device active too long
|
807 |
09/03/2026 09:48:57 |
|
1703 |
Elevator Failure Start failed
|
307 |
05/03/2026 10:01:11 |
|
1702 |
Elevator Failure Start timeout
|
178 |
05/03/2026 10:27:32 |
| SYSRCA |
|
Réception Appel Cyclique |
97 |
10/03/2026 00:55:00 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
19 |
07/03/2026 02:09:31 |
|
1094 |
Elevator Failure Induced noise in landing door contact |
18 |
20/02/2026 19:37:17 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
12 |
05/03/2026 11:04:18 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
07/01/2026 09:03:28 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
8 |
05/03/2026 10:28:41 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
6 |
07/01/2026 09:14:17 |
|
1606 |
Elevator Failure Car door closing failed, too many closing trials
|
6 |
10/01/2026 10:10:42 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
07/01/2026 08:52:49 |
|
1009 |
Elevator Failure Safety circuit: Emergency exit (C3)
|
4 |
07/01/2026 08:56:46 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
07/01/2026 08:56:52 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
4 |
07/01/2026 08:59:25 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
05/01/2026 11:06:50 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
05/01/2026 11:06:50 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
4 |
05/01/2026 11:13:20 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
01/03/2026 19:56:30 |
|
102 |
Temporary Fault Test Alarm |
1 |
07/01/2026 09:05:54 |
|
1613 |
Elevator Failure Car light failed
|
1 |