| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 06:46:59 |
|
1607 |
Elevator Failure Reopen device active too long
|
70 |
09/03/2026 11:36:22 |
|
1702 |
Elevator Failure Start timeout
|
6 |
02/02/2026 10:52:57 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
30/12/2025 12:08:01 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
13/02/2026 09:37:00 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
3 |
13/02/2026 09:37:00 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
2 |
13/02/2026 09:37:08 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
2 |
13/02/2026 09:31:45 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
2 |
13/02/2026 09:33:41 |
|
1099 |
Elevator Failure Main stop switch open |
2 |
13/02/2026 09:31:45 |
|
1066 |
Elevator Failure TTS2 communication fault |
1 |
13/02/2026 09:37:06 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
1 |
13/02/2026 09:31:45 |