| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 22:05:50 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
39 |
23/01/2026 14:40:54 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
35 |
08/01/2026 15:43:30 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
35 |
08/01/2026 15:44:18 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
20 |
10/12/2025 12:44:45 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
20 |
10/12/2025 12:12:21 |
|
1055 |
Elevator Failure Safety circuit: power supply voltage out of 10 % range
|
20 |
23/12/2025 11:49:32 |
|
1115 |
Elevator Failure KCEMSC board failure - Safety input power supply
|
20 |
08/01/2026 15:45:05 |
|
1117 |
Elevator Failure KMI stop switch active
|
18 |
08/01/2026 15:14:04 |
|
1009 |
Elevator Failure Safety circuit: Emergency exit (C3)
|
12 |
08/01/2026 15:25:04 |
|
1013 |
Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
|
12 |
08/01/2026 15:14:08 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
10 |
08/01/2026 15:42:44 |
|
1057 |
Elevator Failure Safety circuit: power supply voltage out of 20 % range
|
9 |
08/01/2026 15:14:10 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
8 |
08/01/2026 15:14:08 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
8 |
08/01/2026 16:18:19 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
6 |
08/01/2026 15:14:00 |
|
1034 |
Elevator Failure safety circuit: Buffers supervision. Down input failure
|
5 |
23/12/2025 11:55:46 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
5 |
08/01/2026 15:14:00 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
10/12/2025 12:04:36 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
4 |
10/12/2025 12:03:40 |
|
1607 |
Elevator Failure Reopen device active too long
|
4 |
27/02/2026 09:39:56 |
|
103 |
False Alarm False Alarm |
3 |
23/01/2026 12:32:18 |
|
1056 |
Elevator Failure Safety circuit: power supply voltage out of 15 % range
|
3 |
23/12/2025 11:55:45 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
3 |
08/01/2026 15:27:17 |
|
102 |
Temporary Fault Test Alarm |
2 |
10/12/2025 12:35:15 |
|
1703 |
Elevator Failure Start failed
|
2 |
08/01/2026 16:26:52 |