Suivi Activite Telesurveillance 43816085


Infos Telalarme
N° Transmetteur 43816085
N° Equipement 43816085
Voie
N° de ligne telephonique 882397127093353
Equipements sur la meme ligne Telephonique 43816085,
Modele et profil TS KCE - DEFAULT KONE 3G INTERNATIONAL
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 16:58:25
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 175
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1607 Elevator Failure Reopen device active too long 63 09/03/2026 12:25:59
SYSRCA Réception Appel Cyclique 63 06/02/2026 00:38:03
1031 Elevator Failure Safety circuit: Landing door opened during drive 53 06/03/2026 05:56:18
1129 Elevator Failure Inspection drive unit stop button active 27 04/03/2026 09:21:54
1011 Elevator Failure Car door contact opened during drive (C5) 26 06/03/2026 05:56:18
1024 Elevator Failure Hoistway door bypass switch active 8 04/03/2026 09:22:25
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 8 04/03/2026 09:29:54
1091 Elevator Failure Lift on final limit magnet 8 04/03/2026 09:29:54
1117 Elevator Failure KMI stop switch active 6 19/01/2026 11:10:20
1008 Elevator Failure Safety circuit: Safety gear (C2) 4 04/03/2026 09:21:37
1009 Elevator Failure Safety circuit: Emergency exit (C3) 4 04/03/2026 09:23:48
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 4 04/03/2026 10:04:35
1702 Elevator Failure Start timeout 4 03/03/2026 15:15:35
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 4 04/03/2026 10:18:06
4018 Elevator Failure KCEAPM has no connection to KCECPU 4 03/03/2026 11:26:49
1010 Elevator Failure Safety circuit: blocking device (C4) 2 04/03/2026 09:23:59
1839 Elevator Failure KCEMSC missing from TTS-1 2 01/03/2026 22:00:57
1840 Elevator Failure KCEMSC missing from TTS-2 2 01/03/2026 22:00:57
103 False Alarm False Alarm 1 13/02/2026 10:49:36