| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 15:25:38 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
20 |
13/02/2026 09:00:04 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
19 |
13/02/2026 09:10:28 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
15 |
13/02/2026 09:08:19 |
|
1607 |
Elevator Failure Reopen device active too long
|
10 |
07/03/2026 10:55:21 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
7 |
13/02/2026 08:50:07 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
6 |
13/02/2026 08:50:58 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
6 |
13/02/2026 09:49:08 |
|
1009 |
Elevator Failure Safety circuit: Emergency exit (C3)
|
4 |
13/02/2026 08:58:55 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
13/02/2026 08:54:01 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
13/02/2026 08:49:28 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
4 |
13/02/2026 08:45:20 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
13/02/2026 08:49:28 |
|
102 |
Temporary Fault Test Alarm |
3 |
13/02/2026 09:11:17 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
2 |
13/02/2026 08:50:07 |
|
1614 |
Elevator Failure Car door close end limit stuck
|
2 |
21/02/2026 09:13:33 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
13/02/2026 08:59:40 |
|
103 |
False Alarm False Alarm |
1 |
13/02/2026 08:42:50 |