1607 |
Elevator Failure Reopen device active too long
|
46 |
03/03/2026 06:56:26 |
|
2339 |
Elevator Failure KCEDZS 24 V power supply failure |
20 |
12/02/2026 14:09:55 |
|
1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
12 |
12/02/2026 14:09:55 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
11 |
12/02/2026 13:38:14 |
|
1000 |
Elevator Failure Serial communication broken on board (both TTS channels)
|
8 |
12/02/2026 13:37:48 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
8 |
17/02/2026 14:58:02 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
5 |
09/02/2026 15:55:35 |
|
1003 |
Elevator Failure Serial communication broken on board (TTS-2)
|
4 |
12/02/2026 13:37:48 |
|
2000 |
Elevator Failure Missing COP
|
4 |
12/02/2026 13:37:51 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
3 |
09/01/2026 18:30:54 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
3 |
09/01/2026 18:30:54 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
22/12/2025 07:05:00 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
13/02/2026 16:32:31 |
|
103 |
False Alarm False Alarm |
1 |
14/02/2026 11:04:57 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
1 |
09/02/2026 15:45:38 |