| SYSRCA |
|
Réception Appel Cyclique |
95 |
09/03/2026 11:00:34 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
93 |
05/01/2026 14:39:52 |
|
1607 |
Elevator Failure Reopen device active too long
|
42 |
09/03/2026 08:49:02 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
34 |
13/02/2026 10:01:28 |
|
1117 |
Elevator Failure KMI stop switch active
|
32 |
05/01/2026 14:33:32 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
24 |
13/02/2026 09:41:07 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
14 |
13/02/2026 09:29:44 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
14 |
15/12/2025 15:23:49 |
|
1099 |
Elevator Failure Main stop switch open |
13 |
15/12/2025 15:23:49 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
12 |
24/02/2026 03:22:49 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
11 |
24/02/2026 03:22:49 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
10 |
15/12/2025 15:28:27 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
9 |
15/12/2025 15:17:14 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
8 |
13/02/2026 10:20:48 |
|
1009 |
Elevator Failure Safety circuit: Emergency exit (C3)
|
7 |
13/02/2026 09:31:11 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
7 |
05/01/2026 15:40:01 |
|
1023 |
Elevator Failure Car door bypass switch active
|
6 |
15/12/2025 15:06:56 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
13/02/2026 10:19:45 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
13/02/2026 09:30:38 |
|
102 |
Temporary Fault Test Alarm |
2 |
13/02/2026 10:08:11 |
|
1082 |
Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
|
2 |
15/12/2025 15:05:46 |
|
1703 |
Elevator Failure Start failed
|
2 |
13/02/2026 10:05:30 |
|
1113 |
Elevator Failure TTS communication stuck
|
1 |
15/12/2025 15:32:14 |