| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 04:45:34 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
20 |
08/01/2026 09:40:08 |
|
1607 |
Elevator Failure Reopen device active too long
|
9 |
01/03/2026 15:01:54 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
8 |
08/01/2026 09:35:37 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
08/01/2026 09:34:03 |
|
1613 |
Elevator Failure Car light failed
|
8 |
09/03/2026 09:02:57 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
08/01/2026 09:45:39 |
|
1117 |
Elevator Failure KMI stop switch active
|
4 |
08/01/2026 09:34:47 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
3 |
25/02/2026 02:43:47 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
19/02/2026 10:49:41 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
08/01/2026 11:39:42 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |