| SYSRCA |
|
Réception Appel Cyclique |
95 |
10/03/2026 03:29:53 |
|
1607 |
Elevator Failure Reopen device active too long
|
70 |
08/03/2026 08:07:07 |
|
1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
24 |
04/03/2026 12:57:19 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
20 |
08/01/2026 09:14:05 |
|
2337 |
Elevator Failure KCEDZS board failure - Faulty magnet sensor |
14 |
04/03/2026 12:57:19 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
12 |
30/01/2026 12:12:10 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
12 |
08/01/2026 09:22:48 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
7 |
08/01/2026 09:04:25 |
|
1702 |
Elevator Failure Start timeout
|
6 |
17/12/2025 15:41:41 |
|
1613 |
Elevator Failure Car light failed
|
5 |
09/03/2026 09:02:58 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
08/01/2026 09:03:25 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
4 |
08/01/2026 09:07:04 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
4 |
17/12/2025 16:11:30 |
|
1703 |
Elevator Failure Start failed
|
4 |
17/12/2025 15:45:18 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
09/03/2026 10:28:11 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
09/03/2026 10:28:11 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
4 |
08/01/2026 10:09:43 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
16/01/2026 09:50:10 |
|
103 |
False Alarm False Alarm |
1 |
04/03/2026 13:34:42 |