| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 17:58:51 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
40 |
04/03/2026 17:40:47 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
23 |
27/02/2026 10:43:43 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
20 |
27/02/2026 10:45:53 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
13 |
27/02/2026 11:59:24 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
12 |
27/02/2026 09:31:04 |
|
1099 |
Elevator Failure Main stop switch open |
10 |
27/02/2026 09:31:04 |
|
1111 |
Elevator Failure KCEFUI SPI failure |
10 |
27/02/2026 10:53:35 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
8 |
27/02/2026 10:55:19 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
8 |
27/02/2026 09:33:29 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
27/02/2026 09:29:57 |
|
1141 |
Elevator Failure Safety circuit: Inspection down limit
|
8 |
26/01/2026 09:29:48 |
|
1117 |
Elevator Failure KMI stop switch active
|
7 |
27/02/2026 10:55:05 |
|
1000 |
Elevator Failure Serial communication broken on board (both TTS channels)
|
6 |
25/01/2026 19:28:53 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
6 |
25/01/2026 19:31:49 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
6 |
04/03/2026 17:48:17 |
|
1075 |
Elevator Failure KCEFUI board disconnected
|
6 |
27/02/2026 10:53:18 |
|
1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
6 |
25/01/2026 19:28:53 |
|
2339 |
Elevator Failure KCEDZS 24 V power supply failure |
6 |
25/01/2026 19:28:46 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
4 |
27/02/2026 09:54:08 |
|
1132 |
Elevator Failure Pit inspection mode reset input active too long |
4 |
27/02/2026 11:08:11 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
4 |
27/02/2026 10:13:15 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
27/02/2026 10:55:11 |
|
1607 |
Elevator Failure Reopen device active too long
|
3 |
26/01/2026 10:47:41 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
3 |
27/02/2026 10:55:11 |
|
2000 |
Elevator Failure Missing COP
|
3 |
25/01/2026 19:28:52 |
|
1003 |
Elevator Failure Serial communication broken on board (TTS-2)
|
2 |
25/01/2026 18:56:20 |
|
101 |
Real Alarm Real Alarm |
2 |
25/01/2026 18:59:38 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
2 |
27/02/2026 10:42:34 |
|
1055 |
Elevator Failure Safety circuit: power supply voltage out of 10 % range
|
2 |
16/02/2026 09:47:50 |
|
1702 |
Elevator Failure Start timeout
|
2 |
27/02/2026 09:36:00 |
|
1703 |
Elevator Failure Start failed
|
2 |
27/02/2026 11:08:19 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
25/12/2025 18:48:57 |