| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 20:40:02 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
43 |
27/02/2026 12:02:45 |
|
1111 |
Elevator Failure KCEFUI SPI failure |
35 |
27/02/2026 11:51:57 |
|
1182 |
Elevator Failure KCEMSC configuration failure - DIP position changed
|
26 |
27/02/2026 11:56:28 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
25 |
27/02/2026 11:54:41 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
24 |
22/01/2026 16:21:43 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
24 |
27/02/2026 11:45:51 |
|
1075 |
Elevator Failure KCEFUI board disconnected
|
22 |
27/02/2026 11:51:31 |
|
1033 |
Elevator Failure safety circuit: Buffers supervision. Up input failure
|
21 |
27/02/2026 11:52:15 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
18 |
22/01/2026 16:57:27 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
18 |
27/02/2026 11:54:32 |
|
1034 |
Elevator Failure safety circuit: Buffers supervision. Down input failure
|
16 |
22/01/2026 16:20:29 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
16 |
27/02/2026 11:54:32 |
|
1117 |
Elevator Failure KMI stop switch active
|
12 |
27/02/2026 11:54:31 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
10 |
22/01/2026 12:21:40 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
10 |
22/01/2026 12:21:40 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
22/01/2026 10:17:05 |
|
1081 |
Elevator Failure KCEMSC board failure - Input comparison
|
6 |
22/01/2026 12:21:32 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
6 |
27/02/2026 12:56:48 |
|
1607 |
Elevator Failure Reopen device active too long
|
5 |
23/01/2026 12:15:43 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
22/01/2026 11:12:41 |
|
1013 |
Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
|
4 |
22/01/2026 10:24:45 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
4 |
22/01/2026 16:55:55 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
4 |
27/02/2026 13:00:32 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
3 |
22/01/2026 10:17:13 |
|
1099 |
Elevator Failure Main stop switch open |
3 |
22/01/2026 10:17:13 |