| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 07:25:32 |
|
1607 |
Elevator Failure Reopen device active too long
|
37 |
25/02/2026 14:51:20 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
16 |
04/03/2026 11:37:46 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
16 |
04/03/2026 12:57:35 |
|
1082 |
Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
|
14 |
04/03/2026 13:09:41 |
|
1117 |
Elevator Failure KMI stop switch active
|
12 |
04/03/2026 12:16:31 |
|
1000 |
Elevator Failure Serial communication broken on board (both TTS channels)
|
7 |
04/03/2026 12:18:40 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
7 |
04/03/2026 11:39:47 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
7 |
04/03/2026 12:13:58 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
7 |
07/03/2026 16:15:50 |
|
1099 |
Elevator Failure Main stop switch open |
6 |
04/03/2026 12:13:58 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
5 |
04/03/2026 12:18:40 |
|
1003 |
Elevator Failure Serial communication broken on board (TTS-2)
|
4 |
04/03/2026 12:18:41 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
4 |
04/03/2026 13:10:26 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
4 |
04/03/2026 11:46:33 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
04/03/2026 13:10:18 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
04/03/2026 13:10:18 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
3 |
04/03/2026 12:12:17 |
|
102 |
Temporary Fault Test Alarm |
2 |
04/03/2026 11:33:36 |
|
1830 |
Elevator Failure LON communication error
|
2 |
23/01/2026 04:29:44 |
|
2000 |
Elevator Failure Missing COP
|
1 |
04/03/2026 12:18:28 |
|
4017 |
Elevator Failure KCEAPM 12V power failed (battery failure)
|
1 |
04/03/2026 13:18:22 |