| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 12:05:37 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
28 |
17/02/2026 10:26:30 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
27 |
17/02/2026 10:26:30 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
23 |
17/02/2026 10:26:29 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
17 |
17/02/2026 10:09:08 |
|
1099 |
Elevator Failure Main stop switch open |
12 |
11/02/2026 13:57:21 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
12 |
17/02/2026 10:45:31 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
9 |
17/02/2026 11:15:10 |
|
1012 |
Elevator Failure Rear car door contact opened during drive (C6)
|
8 |
17/02/2026 10:22:18 |
|
1034 |
Elevator Failure safety circuit: Buffers supervision. Down input failure
|
7 |
17/02/2026 10:09:13 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
7 |
11/02/2026 10:59:22 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
6 |
11/02/2026 10:59:30 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
6 |
17/02/2026 10:10:28 |
|
1009 |
Elevator Failure Safety circuit: Emergency exit (C3)
|
4 |
17/02/2026 10:07:58 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
4 |
17/02/2026 10:26:30 |
|
1607 |
Elevator Failure Reopen device active too long
|
4 |
04/01/2026 03:46:26 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
27/01/2026 04:11:24 |
|
1007 |
Elevator Failure Motor parameterization fault |
2 |
17/02/2026 09:45:40 |
|
1064 |
Elevator Failure Movement risk during start or stop sequence (HW failure) counter |
2 |
11/02/2026 10:28:13 |
|
1035 |
Elevator Failure Unintended movement
|
1 |
11/02/2026 10:28:45 |
|
1117 |
Elevator Failure KMI stop switch active
|
1 |
11/02/2026 10:35:55 |
|
1799 |
Elevator Failure Self check mode stuck.
|
1 |
11/02/2026 10:29:01 |