| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 21:53:39 |
|
1607 |
Elevator Failure Reopen device active too long
|
36 |
04/03/2026 14:41:51 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
19 |
13/02/2026 15:32:50 |
|
1040 |
Elevator Failure Drive time supervision
|
12 |
13/02/2026 16:07:05 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
10 |
13/02/2026 16:07:27 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
8 |
13/02/2026 16:12:50 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
8 |
13/02/2026 15:31:00 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
8 |
13/02/2026 16:07:19 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
8 |
13/02/2026 16:07:19 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
8 |
04/02/2026 13:45:13 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
6 |
04/02/2026 13:44:48 |
|
1703 |
Elevator Failure Start failed
|
3 |
13/02/2026 15:33:27 |
|
1830 |
Elevator Failure LON communication error
|
2 |
20/01/2026 22:07:05 |