1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
96 |
07/03/2026 15:52:53 |
| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 06:46:53 |
|
2337 |
Elevator Failure KCEDZS board failure - Faulty magnet sensor |
38 |
07/03/2026 15:52:53 |
|
1607 |
Elevator Failure Reopen device active too long
|
16 |
01/03/2026 13:39:52 |
|
1009 |
Elevator Failure Safety circuit: Emergency exit (C3)
|
8 |
13/01/2026 09:57:01 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
13/01/2026 09:34:35 |
|
1613 |
Elevator Failure Car light failed
|
8 |
09/03/2026 09:03:30 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
7 |
13/01/2026 09:41:23 |
|
1099 |
Elevator Failure Main stop switch open |
7 |
13/01/2026 09:41:23 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
13/01/2026 09:36:20 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
13/01/2026 09:43:32 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
13/01/2026 10:00:16 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
4 |
13/01/2026 09:44:07 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
4 |
13/01/2026 09:43:38 |
|
1614 |
Elevator Failure Car door close end limit stuck
|
2 |
25/01/2026 17:36:34 |
|
1702 |
Elevator Failure Start timeout
|
2 |
13/01/2026 10:00:19 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
05/03/2026 13:32:49 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
05/03/2026 13:32:49 |