Suivi Activite Telesurveillance 44063131


Infos Telalarme
N° Transmetteur 44063131
N° Equipement 44063131
Voie
N° de ligne telephonique 882397124899531
Equipements sur la meme ligne Telephonique 44063131,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 10/03/2026 00:34:32
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 181
Option contrat "Lien vocal" Inclus
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 95 10/03/2026 01:34:27
1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range 57 08/02/2026 19:42:01
1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range 35 08/02/2026 19:44:14
1702 Elevator Failure Start timeout 24 06/03/2026 15:38:01
1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8) 15 26/02/2026 13:31:59
1099 Elevator Failure Main stop switch open 15 26/02/2026 14:19:16
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 14 26/02/2026 14:19:16
1011 Elevator Failure Car door contact opened during drive (C5) 6 24/12/2025 09:50:26
1703 Elevator Failure Start failed 6 26/02/2026 11:55:13
1140 Elevator Failure Safety circuit: Inspection up limit 5 26/02/2026 13:31:59
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 4 26/02/2026 12:47:12
1115 Elevator Failure KCEMSC board failure - Safety input power supply 4 09/02/2026 01:48:10
4018 Elevator Failure KCEAPM has no connection to KCECPU 4 30/01/2026 10:17:48
1004 Elevator Failure TTS serial communication broken. One channel 3 26/02/2026 14:17:32
1031 Elevator Failure Safety circuit: Landing door opened during drive 3 12/12/2025 11:22:43
1613 Elevator Failure Car light failed 3 30/01/2026 09:16:43
1840 Elevator Failure KCEMSC missing from TTS-2 3 26/02/2026 14:17:20
1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range 2 09/02/2026 01:48:10
1129 Elevator Failure Inspection drive unit stop button active 2 26/02/2026 11:45:56
1830 Elevator Failure LON communication error 2 28/01/2026 03:12:33
1839 Elevator Failure KCEMSC missing from TTS-1 2 28/01/2026 03:12:50
102 Temporary Fault Test Alarm 1 30/01/2026 12:47:17
1024 Elevator Failure Hoistway door bypass switch active 1 26/02/2026 11:55:17
103 False Alarm False Alarm 1 16/02/2026 10:44:01
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 1 08/02/2026 19:44:16
1072 Elevator Failure Energy saving failure 1 08/02/2026 19:44:14
<-- Retour KOF