Suivi Activite Telesurveillance 44082849


Infos Telalarme
N° Transmetteur 44082849
N° Equipement 44082849
Voie
N° de ligne telephonique 882397143421717
Equipements sur la meme ligne Telephonique 44082849,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 06:38:42
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 142
Option contrat "Lien vocal" Ligne GSM (Prix réduit)
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 93 09/03/2026 07:38:37
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 20 06/01/2026 14:00:35
1031 Elevator Failure Safety circuit: Landing door opened during drive 19 06/01/2026 13:49:46
1114 Elevator Failure Pit inspection mode input failure 9 06/01/2026 14:03:56
1091 Elevator Failure Lift on final limit magnet 7 06/01/2026 13:43:38
1839 Elevator Failure KCEMSC missing from TTS-1 7 07/03/2026 09:37:57
1840 Elevator Failure KCEMSC missing from TTS-2 7 07/03/2026 09:37:57
1607 Elevator Failure Reopen device active too long 6 22/02/2026 15:32:19
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 5 06/01/2026 13:43:42
1008 Elevator Failure Safety circuit: Safety gear (C2) 4 06/01/2026 13:59:56
1012 Elevator Failure Rear car door contact opened during drive (C6) 4 19/12/2025 18:43:25
1099 Elevator Failure Main stop switch open 4 06/01/2026 13:43:41
1129 Elevator Failure Inspection drive unit stop button active 4 06/01/2026 13:47:10
1002 Elevator Failure Serial communication broken on board (TTS-1) 3 19/12/2025 16:49:30
102 Temporary Fault Test Alarm 3 06/01/2026 13:40:22
1044 Elevator Failure Drive not OK 3 19/12/2025 16:49:40
1613 Elevator Failure Car light failed 3 04/02/2026 15:23:11
1009 Elevator Failure Safety circuit: Emergency exit (C3) 2 06/01/2026 13:50:15
1010 Elevator Failure Safety circuit: blocking device (C4) 2 06/01/2026 13:50:22
1035 Elevator Failure Unintended movement 2 06/01/2026 13:45:44
1820 Elevator Failure Drive communication broken 2 19/12/2025 16:49:31
4018 Elevator Failure KCEAPM has no connection to KCECPU 2 06/01/2026 14:47:01
101 Real Alarm Real Alarm 1 19/12/2025 18:47:13
103 False Alarm False Alarm 1 19/12/2025 16:47:29
1702 Elevator Failure Start timeout 1 06/01/2026 13:41:35
<-- Retour KOF