| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 16:28:59 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
32 |
15/12/2025 15:57:32 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
28 |
05/03/2026 08:19:07 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
26 |
05/03/2026 08:20:18 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
24 |
05/03/2026 08:20:18 |
|
1607 |
Elevator Failure Reopen device active too long
|
16 |
07/03/2026 11:57:20 |
|
1702 |
Elevator Failure Start timeout
|
12 |
12/02/2026 11:10:30 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
8 |
24/01/2026 19:40:32 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
8 |
15/12/2025 16:27:32 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
6 |
24/01/2026 19:40:32 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
05/03/2026 08:19:35 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
05/03/2026 08:19:35 |
|
1613 |
Elevator Failure Car light failed
|
4 |
17/02/2026 17:00:12 |
|
1013 |
Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
|
2 |
15/12/2025 10:51:47 |
|
1117 |
Elevator Failure KMI stop switch active
|
2 |
05/03/2026 08:19:45 |
|
1703 |
Elevator Failure Start failed
|
2 |
12/02/2026 11:10:48 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
08/02/2026 21:45:55 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
08/02/2026 21:45:55 |