| SYSRCA |
|
Réception Appel Cyclique |
94 |
10/03/2026 01:12:48 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
42 |
13/01/2026 12:08:33 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
38 |
05/03/2026 10:48:05 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
37 |
05/03/2026 10:48:05 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
36 |
05/03/2026 10:48:05 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
33 |
05/03/2026 10:48:05 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
26 |
13/01/2026 12:07:23 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
20 |
13/01/2026 11:03:56 |
|
1117 |
Elevator Failure KMI stop switch active
|
12 |
13/01/2026 11:36:10 |
|
1114 |
Elevator Failure Pit inspection mode input failure |
8 |
13/01/2026 09:52:18 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
8 |
04/03/2026 03:55:25 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
8 |
04/03/2026 03:55:25 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
6 |
13/01/2026 11:28:00 |
|
1607 |
Elevator Failure Reopen device active too long
|
4 |
06/02/2026 11:22:56 |
|
1830 |
Elevator Failure LON communication error
|
4 |
04/03/2026 03:55:08 |
|
100 |
Temporary Fault Unclassified Alarm |
2 |
03/02/2026 16:03:10 |
|
1613 |
Elevator Failure Car light failed
|
2 |
05/02/2026 18:14:31 |
|
1702 |
Elevator Failure Start timeout
|
2 |
13/01/2026 10:50:21 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
13/01/2026 10:55:36 |
|
101 |
Real Alarm Real Alarm |
1 |
04/03/2026 10:09:50 |
|
102 |
Temporary Fault Test Alarm |
1 |
18/12/2025 16:09:54 |