Suivi Activite Telesurveillance 44148474


Infos Telalarme
N° Transmetteur 44148474
N° Equipement 44148474
Voie
N° de ligne telephonique 882397129140638
Equipements sur la meme ligne Telephonique 44148474,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 20:47:09
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 311
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1188 Elevator Failure Safety circuit: Buffers up input (H7) 148 27/02/2026 16:48:59
1039 Elevator Failure Door open monitoring functioned 95 27/02/2026 16:47:03
SYSRCA Réception Appel Cyclique 94 09/03/2026 06:12:54
1034 Elevator Failure safety circuit: Buffers supervision. Down input failure 89 27/02/2026 16:33:26
1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8) 81 27/02/2026 16:48:59
1033 Elevator Failure safety circuit: Buffers supervision. Up input failure 50 27/02/2026 16:48:59
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 40 18/02/2026 17:27:20
1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7) 31 27/02/2026 15:31:32
1004 Elevator Failure TTS serial communication broken. One channel 26 27/02/2026 16:49:07
1111 Elevator Failure KCEFUI SPI failure 26 27/02/2026 16:48:41
1182 Elevator Failure KCEMSC configuration failure - DIP position changed 22 27/02/2026 16:47:06
1839 Elevator Failure KCEMSC missing from TTS-1 22 03/03/2026 14:30:58
1840 Elevator Failure KCEMSC missing from TTS-2 21 03/03/2026 14:30:58
1031 Elevator Failure Safety circuit: Landing door opened during drive 20 27/01/2026 11:12:53
1607 Elevator Failure Reopen device active too long 19 24/02/2026 18:34:24
1075 Elevator Failure KCEFUI board disconnected 16 27/02/2026 16:47:44
1053 Elevator Failure KCEMSC board failure - Safety input cross check 10 18/02/2026 13:54:31
1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range 10 14/02/2026 15:16:16
1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range 8 14/02/2026 21:25:18
1117 Elevator Failure KMI stop switch active 8 27/02/2026 16:48:41
1091 Elevator Failure Lift on final limit magnet 7 27/01/2026 11:24:54
1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range 6 14/02/2026 18:24:12
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 6 18/02/2026 17:06:07
1099 Elevator Failure Main stop switch open 6 18/02/2026 17:06:07
1129 Elevator Failure Inspection drive unit stop button active 6 18/02/2026 17:25:24
1175 Elevator Failure Safety system in Safe mode 6 18/02/2026 13:54:31
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 5 18/02/2026 14:50:45
1008 Elevator Failure Safety circuit: Safety gear (C2) 4 27/01/2026 11:26:43
1081 Elevator Failure KCEMSC board failure - Input comparison 4 27/02/2026 15:27:14
1109 Elevator Failure Landing door not opened after top of car inspection 4 18/02/2026 16:37:47
1115 Elevator Failure KCEMSC board failure - Safety input power supply 4 14/02/2026 21:25:18
1132 Elevator Failure Pit inspection mode reset input active too long 4 14/02/2026 18:41:13
1799 Elevator Failure Self check mode stuck. 4 18/02/2026 13:54:33
1062 Elevator Failure KCEMSC board failure - No reciprocal communication 3 18/02/2026 13:54:31
100 Temporary Fault Unclassified Alarm 2 17/02/2026 17:49:29
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 2 14/02/2026 15:21:22
4018 Elevator Failure KCEAPM has no connection to KCECPU 2 18/02/2026 14:37:29
101 Real Alarm Real Alarm 1 17/02/2026 17:27:12
<-- Retour KOF