1607 |
Elevator Failure Reopen device active too long
|
149 |
06/03/2026 17:29:52 |
| SYSRCA |
|
Réception Appel Cyclique |
102 |
10/03/2026 03:15:56 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
50 |
26/02/2026 18:03:21 |
|
1012 |
Elevator Failure Rear car door contact opened during drive (C6)
|
46 |
26/02/2026 18:03:21 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
37 |
22/12/2025 15:17:04 |
|
1033 |
Elevator Failure safety circuit: Buffers supervision. Up input failure
|
14 |
22/12/2025 10:17:06 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
12 |
16/02/2026 05:46:05 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
11 |
16/02/2026 05:46:05 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
10 |
22/12/2025 10:16:51 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
8 |
22/12/2025 10:16:35 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
5 |
22/12/2025 15:19:11 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
4 |
22/12/2025 10:11:11 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
23/02/2026 21:19:30 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
23/02/2026 21:19:30 |
|
1023 |
Elevator Failure Car door bypass switch active
|
2 |
22/12/2025 10:11:13 |
|
1117 |
Elevator Failure KMI stop switch active
|
2 |
22/12/2025 10:11:08 |
|
1181 |
Elevator Failure Door bypass switch misuse |
2 |
22/12/2025 10:11:13 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
29/12/2025 12:41:40 |