Suivi Activite Telesurveillance 44194444


Infos Telalarme
N° Transmetteur 44194444
N° Equipement 44194444
Voie
N° de ligne telephonique 882399991510342
Equipements sur la meme ligne Telephonique 44194444,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 09:24:49
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 486
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1003 Elevator Failure Serial communication broken on board (TTS-2) 443 03/02/2026 09:46:41
SYSRCA Réception Appel Cyclique 96 09/03/2026 10:24:44
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 74 03/02/2026 10:17:09
1043 Elevator Failure Start permit fault 62 23/12/2025 08:20:20
1190 Elevator Failure Device picked input dropped while lift running 52 23/12/2025 08:20:18
1109 Elevator Failure Landing door not opened after top of car inspection 26 03/02/2026 10:14:27
1702 Elevator Failure Start timeout 19 23/12/2025 08:20:23
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 19 11/02/2026 17:09:07
1129 Elevator Failure Inspection drive unit stop button active 16 03/02/2026 10:31:43
1081 Elevator Failure KCEMSC board failure - Input comparison 13 30/01/2026 14:07:11
1175 Elevator Failure Safety system in Safe mode 13 31/01/2026 00:14:26
1607 Elevator Failure Reopen device active too long 12 07/03/2026 10:28:40
1839 Elevator Failure KCEMSC missing from TTS-1 12 03/02/2026 10:13:18
1117 Elevator Failure KMI stop switch active 11 30/01/2026 14:14:16
1799 Elevator Failure Self check mode stuck. 10 30/01/2026 14:14:16
1024 Elevator Failure Hoistway door bypass switch active 9 03/02/2026 10:31:45
1840 Elevator Failure KCEMSC missing from TTS-2 9 03/02/2026 10:13:18
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 8 30/01/2026 13:33:26
1099 Elevator Failure Main stop switch open 8 30/01/2026 13:33:26
1212 Elevator Failure KCECCG board failure - 24V power supply 8 30/01/2026 10:38:01
1062 Elevator Failure KCEMSC board failure - No reciprocal communication 7 30/01/2026 14:14:16
1613 Elevator Failure Car light failed 3 13/02/2026 01:50:57
1004 Elevator Failure TTS serial communication broken. One channel 2 03/02/2026 10:13:26
1097 Elevator Failure Device picked fault 2 19/01/2026 09:30:39
1181 Elevator Failure Door bypass switch misuse 2 30/01/2026 14:13:32
200 System failure: KCE System failure: KCE 2 30/01/2026 11:10:59
4018 Elevator Failure KCEAPM has no connection to KCECPU 2 20/01/2026 18:11:39
1007 Elevator Failure Safety circuit: Final limit (C1) 1 30/01/2026 10:37:49
1008 Elevator Failure Safety circuit: Safety gear (C2) 1 30/01/2026 10:37:49
1009 Elevator Failure Safety circuit: Emergency exit (C3) 1 30/01/2026 10:37:49
1010 Elevator Failure Safety circuit: blocking device (C4) 1 30/01/2026 10:37:49
1140 Elevator Failure Safety circuit: Inspection up limit 1 30/01/2026 10:37:49
1141 Elevator Failure Safety circuit: Inspection down limit 1 30/01/2026 10:37:49
1178 Elevator Failure KCEMSC board failure 1 31/01/2026 00:14:26
4017 Elevator Failure KCEAPM 12V power failed (battery failure) 1 30/01/2026 11:52:17
<-- Retour KOF