Suivi Activite Telesurveillance 44226559


Infos Telalarme
N° Transmetteur 44226559
N° Equipement 44226559
Voie
N° de ligne telephonique 882397127095335
Equipements sur la meme ligne Telephonique 44226559,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 20:30:58
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 166
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 94 09/03/2026 21:30:50
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 30 08/01/2026 15:03:07
1129 Elevator Failure Inspection drive unit stop button active 27 08/01/2026 14:36:34
1024 Elevator Failure Hoistway door bypass switch active 20 08/01/2026 14:48:33
1094 Elevator Failure Induced noise in landing door contact 18 13/12/2025 03:38:48
1004 Elevator Failure TTS serial communication broken. One channel 13 29/12/2025 10:48:43
1031 Elevator Failure Safety circuit: Landing door opened during drive 12 29/12/2025 11:16:43
1839 Elevator Failure KCEMSC missing from TTS-1 12 05/02/2026 08:25:47
1840 Elevator Failure KCEMSC missing from TTS-2 12 05/02/2026 08:25:47
1607 Elevator Failure Reopen device active too long 10 07/03/2026 18:32:37
1702 Elevator Failure Start timeout 8 08/01/2026 14:39:28
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 5 17/12/2025 12:07:59
1037 Elevator Failure Car door: stuck contact 4 13/12/2025 03:06:19
1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range 4 12/12/2025 15:59:37
1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs 4 17/12/2025 10:59:06
1109 Elevator Failure Landing door not opened after top of car inspection 4 29/12/2025 10:29:03
1115 Elevator Failure KCEMSC board failure - Safety input power supply 4 12/12/2025 15:59:40
4018 Elevator Failure KCEAPM has no connection to KCECPU 4 15/12/2025 16:19:46
1117 Elevator Failure KMI stop switch active 3 13/12/2025 09:47:03
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 2 12/12/2025 15:59:37
1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range 2 13/12/2025 04:10:30
1072 Elevator Failure Energy saving failure 2 12/12/2025 15:59:37
1614 Elevator Failure Car door close end limit stuck 2 14/12/2025 16:48:47
1703 Elevator Failure Start failed 2 08/01/2026 15:03:53
102 Temporary Fault Test Alarm 1 19/02/2026 13:42:36
<-- Retour KOF