| SYSRCA |
|
Réception Appel Cyclique |
97 |
09/03/2026 14:18:30 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
9 |
09/03/2026 10:29:48 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
7 |
09/03/2026 11:20:20 |
| SYSEVE |
162001 |
System Failure: low: Analyzer MONITORING ON |
6 |
12/12/2026 16:33:13 |
| SYSEVE |
162006 |
System Failure: low: Analyzer DATA_LINK |
6 |
12/12/2026 16:33:13 |
| SYSFAI |
151014 |
System Failure OK: low: Rif ANALYZER POWER FAIL |
5 |
09/03/2026 10:30:33 |
| DEBEVE |
153104 |
System Failure: low: Rif RIF RESET: RESET BY USER |
2 |
15/02/2026 14:20:49 |
| SYSEVE |
152000 |
System Failure: low: Rif ALARM FROM CAR |
2 |
09/03/2026 11:13:04 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
2 |
09/03/2026 09:50:05 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
2 |
09/03/2026 09:44:23 |
|
255255 |
Test Alarm (Direct Call) Test Alarm (Direct Call) |
1 |
16/01/2026 10:38:04 |
|
255255 |
Unclassified Alarm (Direct Call) Unclassified Alarm (Direct Call) |
1 |
09/03/2026 11:14:13 |
| SYSEVE |
152004 |
System Failure: low: Rif TEST ALARM FROM CAR |
1 |
09/03/2026 11:14:36 |
| SYSEVE |
162010 |
System Failure: low: Analyzer PARAMETER CHANGE |
1 |
12/12/2026 16:33:13 |
| SYSEVE |
163004 |
System Failure OK: low: Analyzer CONFIGURATION SET |
1 |
12/12/2026 16:33:13 |
| SYSFAI |
151013 |
System Failure OK: low: Rif NO CONNECTION TO ANALYZER |
1 |
15/01/2026 16:11:33 |
| SYSFAI |
151015 |
System Failure: low: Rif ON SITE NETWORK CONFIGURATION ERROR |
1 |
16/01/2026 14:18:53 |