| SYSRCA |
|
Réception Appel Cyclique |
165 |
10/03/2026 01:36:32 |
| SYSEVE |
153000 |
System Failure: low: Rif ENGINEER ON SITE |
8 |
01/02/2026 22:23:14 |
| SYSEVE |
153000 |
System Failure OK: low: Rif ENGINEER ON SITE |
7 |
01/02/2026 22:23:14 |
| SYSFAI |
151009 |
System Failure OK: low: Rif MAIN POWER FAIL |
7 |
05/02/2026 09:00:29 |
| SYSFAI |
151009 |
System Failure: low: Rif MAIN POWER FAIL |
7 |
05/02/2026 09:00:26 |
| SYSFAI |
151015 |
System Failure: low: Rif ON SITE NETWORK CONFIGURATION ERROR |
7 |
05/02/2026 09:01:01 |
| SYSFAI |
151013 |
System Failure OK: low: Rif NO CONNECTION TO ANALYZER |
5 |
05/02/2026 08:58:01 |
|
255255 |
Unclassified Alarm (Direct Call) Unclassified Alarm (Direct Call) |
2 |
10/12/2025 19:59:30 |
| SYSFAI |
151007 |
System Failure: low: Rif BATTERY FAIL |
2 |
01/02/2026 22:23:14 |
| SYSFAI |
151008 |
System Failure: low: Rif BATTERY VOLTAGE LOW |
2 |
01/02/2026 22:23:14 |
|
255255 |
Emergency Alarm (Direct Call) Emergency Alarm (Direct Call) |
1 |
10/12/2025 20:26:06 |
| DEBEVE |
153104 |
System Failure: low: Rif RIF RESET: RESET BY USER |
1 |
07/01/2026 01:37:54 |
| SYSFAI |
151009 |
System Failure OK: Rif MAIN POWER FAIL |
1 |
28/01/2026 13:55:24 |
| SYSFAI |
151009 |
System Failure: Rif MAIN POWER FAIL |
1 |
28/01/2026 13:46:06 |