| SYSRCA |
|
Réception Appel Cyclique |
99 |
10/03/2026 03:27:15 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
47 |
03/03/2026 16:05:41 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
46 |
03/03/2026 15:45:50 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
43 |
03/03/2026 15:42:37 |
|
200 |
System failure: KCE System failure: KCE |
24 |
29/01/2026 15:27:19 |
|
1607 |
Elevator Failure Reopen device active too long
|
17 |
09/03/2026 13:29:52 |
|
1009 |
Elevator Failure Safety circuit: Emergency exit (C3)
|
13 |
03/03/2026 16:03:35 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
12 |
03/03/2026 16:05:31 |
|
2339 |
Elevator Failure KCEDZS 24 V power supply failure |
10 |
03/03/2026 15:35:22 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
8 |
03/03/2026 16:05:00 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
03/03/2026 15:40:07 |
|
1820 |
Elevator Failure Drive communication broken
|
6 |
03/03/2026 15:35:23 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
03/03/2026 16:02:56 |
|
102 |
Temporary Fault Test Alarm |
4 |
03/03/2026 15:41:47 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
4 |
03/03/2026 16:02:18 |
|
1034 |
Elevator Failure safety circuit: Buffers supervision. Down input failure
|
4 |
03/03/2026 16:06:18 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
2 |
03/03/2026 15:35:53 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
2 |
03/03/2026 16:09:09 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
06/02/2026 13:26:21 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
2 |
06/02/2026 13:32:34 |