Suivi Activite Telesurveillance 43332448


Infos Telalarme
N° Transmetteur 43332448
N° Equipement 43332448
Voie
N° de ligne telephonique 882397128412416
Equipements sur la meme ligne Telephonique 43332447, 43332448,
Modele et profil TS KCE - DEFAULT
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 10/03/2026 02:47:34
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 153
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 100 10/03/2026 03:47:16
1039 Elevator Failure Door open monitoring functioned 29 03/03/2026 15:27:11
1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8) 24 03/03/2026 14:34:36
1188 Elevator Failure Safety circuit: Buffers up input (H7) 21 03/03/2026 14:39:45
1129 Elevator Failure Inspection drive unit stop button active 11 03/03/2026 15:01:06
1141 Elevator Failure Safety circuit: Inspection down limit 10 03/03/2026 14:59:28
1010 Elevator Failure Safety circuit: blocking device (C4) 8 03/03/2026 14:59:24
1091 Elevator Failure Lift on final limit magnet 7 03/03/2026 14:32:15
1607 Elevator Failure Reopen device active too long 6 09/03/2026 13:50:46
100 Temporary Fault Unclassified Alarm 4 03/03/2026 14:33:49
1009 Elevator Failure Safety circuit: Emergency exit (C3) 4 03/03/2026 14:59:14
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 4 03/03/2026 15:12:28
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 4 03/03/2026 14:28:49
1031 Elevator Failure Safety circuit: Landing door opened during drive 4 03/03/2026 14:58:49
1034 Elevator Failure safety circuit: Buffers supervision. Down input failure 4 03/03/2026 15:02:58
1140 Elevator Failure Safety circuit: Inspection up limit 4 03/03/2026 15:00:17
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 4 03/03/2026 15:39:23
1614 Elevator Failure Car door close end limit stuck 3 09/02/2026 14:39:48
1839 Elevator Failure KCEMSC missing from TTS-1 3 02/02/2026 18:35:05
1840 Elevator Failure KCEMSC missing from TTS-2 3 02/02/2026 18:35:05
1007 Elevator Failure Safety circuit: Final limit (C1) 2 03/03/2026 14:31:04
4002 Elevator Failure KCEAPM phone line missing 2 06/02/2026 13:37:14