Suivi Activite Telesurveillance 44092382


Infos Telalarme
N° Transmetteur 44092382
N° Equipement 44092382
Voie
N° de ligne telephonique 882397127584128
Equipements sur la meme ligne Telephonique 44092382,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS BAVARDE
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 21:03:33
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 462
Option contrat "Lien vocal" Inclus
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7) 220 19/02/2026 11:25:51
1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8) 148 20/02/2026 12:52:41
1011 Elevator Failure Car door contact opened during drive (C5) 99 03/03/2026 10:51:56
1004 Elevator Failure TTS serial communication broken. One channel 91 20/02/2026 12:52:41
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 77 20/02/2026 12:52:38
1607 Elevator Failure Reopen device active too long 61 09/03/2026 10:05:47
1039 Elevator Failure Door open monitoring functioned 57 20/02/2026 12:52:41
1033 Elevator Failure safety circuit: Buffers supervision. Up input failure 52 20/02/2026 12:52:38
SYSRCA Réception Appel Cyclique 52 09/03/2026 14:37:43
1840 Elevator Failure KCEMSC missing from TTS-2 51 20/02/2026 12:52:40
1129 Elevator Failure Inspection drive unit stop button active 46 19/02/2026 10:54:00
1188 Elevator Failure Safety circuit: Buffers up input (H7) 44 20/02/2026 12:52:38
1003 Elevator Failure Serial communication broken on board (TTS-2) 39 19/02/2026 11:26:14
1031 Elevator Failure Safety circuit: Landing door opened during drive 38 03/03/2026 10:51:56
1141 Elevator Failure Safety circuit: Inspection down limit 36 19/02/2026 11:11:15
1006 Elevator Failure TTS line failure 35 20/02/2026 12:52:41
1008 Elevator Failure Safety circuit: Safety gear (C2) 35 18/02/2026 13:51:55
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 35 19/02/2026 11:26:16
1010 Elevator Failure Safety circuit: blocking device (C4) 30 19/02/2026 11:21:38
1140 Elevator Failure Safety circuit: Inspection up limit 23 19/02/2026 11:15:19
1106 Elevator Failure Setup failed 22 19/02/2026 09:40:33
1034 Elevator Failure safety circuit: Buffers supervision. Down input failure 18 20/02/2026 12:21:11
1839 Elevator Failure KCEMSC missing from TTS-1 18 19/02/2026 10:25:58
1024 Elevator Failure Hoistway door bypass switch active 16 18/02/2026 14:33:47
1111 Elevator Failure KCEFUI SPI failure 16 19/02/2026 10:25:53
1117 Elevator Failure KMI stop switch active 16 19/02/2026 10:25:54
1000 Elevator Failure Serial communication broken on board (both TTS channels) 14 19/02/2026 09:47:59
1075 Elevator Failure KCEFUI board disconnected 12 19/02/2026 10:24:39
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 11 19/02/2026 10:43:46
1182 Elevator Failure KCEMSC configuration failure - DIP position changed 11 19/02/2026 09:39:36
1002 Elevator Failure Serial communication broken on board (TTS-1) 10 19/02/2026 09:47:59
1099 Elevator Failure Main stop switch open 10 19/02/2026 10:43:46
1702 Elevator Failure Start timeout 10 28/02/2026 23:41:45
2000 Elevator Failure Missing COP 7 17/02/2026 11:33:58
2303 Elevator Failure Unrecognized magnet 6 17/02/2026 10:22:31
4018 Elevator Failure KCEAPM has no connection to KCECPU 6 19/02/2026 11:35:52
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 5 18/02/2026 15:00:29
1023 Elevator Failure Car door bypass switch active 4 18/02/2026 14:41:22
1035 Elevator Failure Unintended movement 4 18/02/2026 13:39:34
1040 Elevator Failure Drive time supervision 4 18/02/2026 13:50:45
1091 Elevator Failure Lift on final limit magnet 4 18/02/2026 12:18:45
1109 Elevator Failure Landing door not opened after top of car inspection 4 19/02/2026 11:23:36
1132 Elevator Failure Pit inspection mode reset input active too long 4 07/01/2026 09:52:46
1161 Elevator Failure KCEDZS board failure - Self check failed 4 17/02/2026 11:33:52
2339 Elevator Failure KCEDZS 24 V power supply failure 4 17/02/2026 11:33:52
4017 Elevator Failure KCEAPM 12V power failed (battery failure) 4 17/02/2026 11:24:17
1005 Elevator Failure TTS serial communication broken. Both channels 3 19/02/2026 09:47:59
200 System failure: KCE System failure: KCE 3 16/02/2026 13:41:25
100 Temporary Fault Unclassified Alarm 2 20/02/2026 12:08:00
102 Temporary Fault Test Alarm 2 18/02/2026 12:59:04
1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs 2 19/02/2026 10:23:25
1830 Elevator Failure LON communication error 2 25/12/2025 20:35:40
100 Unclassified Alarm Unclassified Alarm 1 19/02/2026 10:21:54
1002 Elevator Failure Braking resistor supervision 1 07/01/2026 10:22:33
<-- Retour KOF